Seahawk Feed Timer Mechanical
-
Metal Casing
-
Wall Mounting/Hanging
Purpose: To control multiple feed pumps (using extension board) on same feed cycle within 24 Hrs (repeats each day) which can be precisely set to 10Sec/20Sec/30 Sec up to 10 Min.
Operation –
· Decide what interval within 24 Hrs you need to feed plants.
· Set main timer (every hour/two hours) by pulling out red pin (15 Minute minimum) at set time of the day. (Say 6am to 6pm each hour then pull one red pin each hour). Main timer will click on for that period.
· Set Feed time (10 Sec to 100 Sec) using middle and top dial of feed timer. Do not disturb bottom setting which is “A”.
· Use Setting table below.
Feed time
|
Top
|
Middle
|
10 Sec
|
10 Sec
|
10
|
20 Sec
|
100Sec
|
2
|
30Sec
|
100Sec
|
3 ( between 2-4)
|
40 sec
|
100Sec
|
4
|
50 Sec
|
100Sec
|
5(between 4-6)
|
60 Sec/ 1 Min
|
10 Min
|
1 ( between 0-2)
|
· Use Extension board and connect all pumps which will use this feed timer on them up to max capacity of 500 W.
· Set real clock time and on main timer dial and plug timer cord to start cycle.
· When main timer clicks on red pin, the feed timer will start feeding pumps (green led flashing) for set time and once time is over it will stop pumps connected and feed cycle is over (Green led steady).
· Main timer will be on for minimum of 15 minutes which will be indicated by red and green led on feed timer.
· Once main timer clicks off it is ready for next cycle in next hour or two as per setting. (green and red LED off)
Important:
Main timer needs power to continue cycle. If plug is removed or power is off main timer will mismatch real time when power is restored. It will continue cycle from the time it was stopped.
Please reset timer to correct real time.
To avoid automatic restart of new cycle use timer reset box. You need to adjust main timer and then reset to start new cycle.