GroLine Waterproof Hydroponic pH Tester HI98118
 
The GroLine HI98118 pH/temperature tester is our latest pocket meter for measuring the pH of a hydroponic nutrient solution. This modern looking meter is only 0.7" thick and extremely ergonomic, fitting comfortably in your hand. The HI98118 has a very large easy to read LCD display that shows both pH and temperature along with calibration, stability and low battery indicators. All operations are simplified to two buttons. One is for turning the meter on/off and the other for automatic one or two point calibration.
 
groline hydroponics ph ec ppm meter
Two-Button Operation
Quick Calibration Mode using Hanna Quick Cal pH/EC Calibration Solution
Extractable Cloth Junction to Extend pH Electrode Life
 
The HI98118 GroLine pocket pH Tester is an affordable way to measure the pH of hydroponic nutrient solutions. The maintaining of an optimal pH is essential to maximize optimum growth. The general rule of thumb is that as pH increases the solubility of minerals and nutrients decrease. It is important that nutrients are soluble for plants to uptake and use for growth. The pH of nutrient solution can also affect the bacteria that fix nitrogen for the plant to use. Every plant has optimum pH levels for growth. Below is a table for the ideal pH range for a variety of plants.
 
The HI98118 can be used to measure the pH in soils as well as nutrient solutions. The North Carolina State University has outlined a procedure known as Pour Through Sampling Method. This method is used for container plants in which 50 ml of leachate is collected from a thoroughly watered plant and then tested.
 
To measure the pH of soil as a slurry the USDA recommends a mixture of 1 part soil to 1 part water. The slurry is allowed to rest for 10 minutes so that the solids will settle out and the pH of liquid above can be measured.
 
The HI98118 is an advanced meter while maintaining simplicity. The front of the meter has two buttons. One is for turning the meter on and off while the other is used to enter the calibration mode. There is a third button in the battery compartment that allows the user to customize the meter to their preference. Customization includes temperature readout in oC or oF, automatic shut off selectable from 8 minutes, 60 minutes or disabled, and lastly the choice of using Hanna's Quick Cal pH/EC standard or traditional buffers values of pH 4.01, 7.01 and 10.01.
 
The HI98118 features a unique extractable cloth junction. The reference junction of a pH electrode, also known as a salt bridge, provides an electrical pathway between the internal reference cell and the sample. Any clogging of the junction will result in a disruption of the electrical pathway. When this happens the readings will be erratic and take a very long time to stabilize. With the Hanna extractable junction a small portion of 1/8" is extracted or pulled to expose a clean surface. With the junction renewed the clogging is cleared allowing the meter to still be used. The overall length of the junction is about 1" so the junction should only be extracted periodically
 
Features
  • Built in temperature sensor for Automatic Temperature Compensated measurements.
  • Renewable junction to clear any clogging that causes readings to drift and be erratic
  • Stability indicator that disappears once a stable reading is obtained
  • Automatic calibration to one or two points at a push of a button
  • Uses Hanna's Quick Cal pH/EC standard with a pH value of 6.86. The standard can also be used to calibrate conductivity meters to 5,000 μS/cm
  • Battery % level remaining displayed at start up.
  • Low battery indicator that is displayed when less than 10% battery life is remaining.

Specifications
 
pH Range
0.00 to 14.00 pH
pH Resolution
0.01 pH; 0.1°C
pH Accuracy
±0.1 pH
Accuracy
±0.1 pH / ±0.5 °C
pH Calibration
automatic, at one or two points using standard buffers (pH 4.01, 7.01,10.01); one point calibration using quick calibration solution
Temperature Compensation
automatic from 0 to 50°C (32 to 122°F)
Battery Type/Life
1.5V CR2032 (1) / approximately 1000 hours of continuous use
Environment
0 to 50°C (32 to 122°F); RH max 100%
Dimensions
160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
Weight
75 g (2.6 oz.)
Ordering Information
HI98118 GroLine is supplied with protective cap, (3) HI50036 Quick Cal calibration sachets (20 ml), (1) HI700601 general purpose cleaning solution sachet (20 ml), (1) CR2032 battery, instruction manual, and quality certificate.

Customer Reviews

This product hasn't been reviewed yet.

Write a review

Write Review

Please enter a valid email address.
This field is required.
Top

Follow Us

Mailing List

Enter your e-mail address to receive our newsletter
Please enter a valid email address.
Email address already subscribed. Continue if you wish to unsubscribe.
Subscribe
Unsubscribe
House and Garden
Hygen
Growhard
Nutrifield
Canna
Rock
Cyco
Growlush
Lumatek
Jungleroom
Lucius
Canfan
Maxfan
Bloom
Trimpro
Sunmaster
Nanolux
Grotek
Phillips
Osram
Twister
Growlush
Ozi Magic
Mountain Air
Seahawk
Gardis Pro
Bluelab
Powerplant
Chef's Aid
Canawipes
Geopot
General Hydroponics
EP
Growool
Sylvania
Plantastic
Xtreme
Flairform
Copyright @ 2011-2019    Juddery P/L ABN: 74 132 886 705     T/as Epping Hydroponics     All prices in AUD and include GST